R40 Insulation: How Thick It Is and Where R40 Is Used in a Home

R40 Insulation: How Thick It Is and Where R40 Is Used in a Home

R40 insulation is about 11 to 12 inches thick in cellulose or fiberglass batts. In blown fiberglass, it’s closer to 16 inches. Closed-cell spray foam gets there in about 6. You’ll find R40 mostly on attic floors and in vaulted ceilings.

Now for the part most guides skip. R40 isn’t enough for a Denver attic. Our climate calls for R-49 to R-60. So R40 is a nice step up from the R-19 we find in a lot of older homes, but it’s not where you want to stop. Below are the exact depths and the places R40 actually makes sense.

How Thick Is R40 Insulation for Each Material?

Somewhere between 6 and 16 inches. It all comes down to how much R-value each inch of the material holds. (R-value is simply how well insulation slows heat. Our guide on what R-value is explains it in plain terms.)

MaterialR-value per inch (about)Thickness for R40
Blown fiberglass (loose fill)R-2.516 inches
Fiberglass battR-3.2 to R-3.611 to 12.5 inches
Blown cellulose (loose fill, settled)R-3.511.5 inches
Open-cell spray foamR-3.6 to R-3.811 inches
Closed-cell spray foamR-6 to R-76 to 6.5 inches

Can You Buy R40 Batts in the United States?

Most U.S. stores jump straight from R38 batts to R49. R40 is a Canadian size. Owens Corning sells R40 fiberglass batts up there at roughly 11 to 11.8 inches thick, in 16-inch and 24-inch widths to match the framing.

Here, people usually get to R40 one of two ways:

  • Blowing loose fill to whatever depth gives R40. Since blown insulation goes in to a measured depth, it can hit any R-value you want. More on that in our guide to what blow-in insulation is.
  • Adding new insulation on top of what’s already there. The R-values just add together.

How Many Inches of Blown-In Insulation Equal R40?

Blown fiberglass needs about 16 inches. Blown cellulose needs about 11.5 inches once it settles. Cellulose is denser, so it fits more R-value into each inch.

Look at the coverage chart printed on any bag. It tells you three things:

  • Minimum settled thickness. How deep it should be after it settles. The R-value is based on this one.
  • Installed thickness. How deep it goes in on day one, which is always more than the settled number.
  • Bags per 1,000 square feet. How much material it takes to hit that R-value.

Cellulose settles about 15 to 20 percent. Blown fiberglass barely settles at all. So a good installer blows cellulose deeper on day one to make up for it. Our guides to blown fiberglass insulation and cellulose R-value per inch go deeper on both.

Where Is R40 Insulation Used in a Home?

R40 on Attic Floors

This is where you’ll see it most. A lot of Denver homes built before 2005 have only about R-19 up there, so going to R40 makes a real difference. That said, if you’re already paying for a team and a blowing machine, pushing on to R-49 or R-60 costs just a little more material.

R40 in Vaulted and Cathedral Ceilings

Vaulted ceilings don’t leave much room between the drywall and the roof deck. A 2×12 rafter is only about 11.25 inches deep, and squeezing R49 of fluffy insulation in there is tough. Closed-cell spray foam can reach about R40 in roughly 6 inches, which can leave space for an air channel if the roof design calls for one. For more, read our guide to ceiling insulation R-value and our blog on what closed-cell spray foam is.

what closed-cell spray foam is.

R40 in Floors Over Garages

The 2021 International Energy Conservation Code (IECC) calls for at least R-30 in a floor over an unheated garage in climate zone 5. Some builders go further, and R40 in a 2×12 floor is doable with dense insulation or spray foam.

R40 in High-Performance Walls

Regular walls never get anywhere near R40. Very energy-efficient homes sometimes do, with thick double-stud walls or a deep layer of foam board on the outside. That’s really a new-build decision, not a typical upgrade.

Is R40 Enough for an Attic in Denver?

It’s below today’s target. Denver is in climate zone 5, and the 2021 IECC sets the attic ceiling level at R-60 for climate zones 4 through 8. The older 2018 code asked for R-49. If you want to see how those numbers have changed over the years, there’s a handy IECC and IRC insulation table from Pacific Northwest National Laboratory.

The code allows R-49 instead of R-60 when the full R-49 depth reaches out over the top of the exterior wall. Getting that right takes raised-heel trusses or careful baffle work at the eaves.

Attic levelWhere it stands
R-19Common in pre-2005 Denver homes
R-30Old code level, now too low for Denver
R-38Previous code level in many cold zones
R-40Better than R-30, still below today’s target
R-49Strong level, allowed with full depth at the eaves
R-602021 IECC level for climate zone 5

Our guides on R49 insulation and how much insulation your attic needs can help you settle on your number.

What Is the Difference Between R38, R40 and R49?

R38 is about 12 inches of standard fiberglass batt, and R49 is about 14 to 16 inches. R40 sits just above R38. Going from R40 up to R49 adds about 22 percent more resistance to heat flow.

Here’s the catch, though. Every extra inch saves a bit less than the one before it. That’s why air sealing matters so much. Air leaks let warm air slide right past the insulation, and sealing them often saves more than those last few inches ever will. Our guide to air sealing an attic walks through how it’s done.

Can You Add Insulation on Top of Old Insulation to Reach R40?

Usually, yes. You can blow new insulation right over the old layer as long as the old stuff is dry, clean and free of rodents. The R-values simply stack.

  • Old 6-inch fiberglass batts: about R-19.
  • New 6 inches of blown cellulose (settled): about R-21.
  • Total: about R-40.

Add three more inches of cellulose and you’re at roughly R-50, and the extra cost is mostly a few more bags. Not sure if your old insulation should stay? Our guide on removing old insulation first explains how we decide.

How Do You Install R40 Attic Insulation Correctly?

  1. Air seal the attic floor. Seal the gaps around lights, plumbing pipes, wire holes and the tops of walls.
  2. Put baffles at the eaves. They keep insulation off the soffit vents so air can still flow.
  3. Block off heat sources. Keep insulation 3 inches away from non-IC lights, chimneys and flues.
  4. Set depth markers. Staple rulers to the framing so you can see the depth all over the attic.
  5. Blow evenly. Low spots lose R-value, so aim for a level surface at or above the target.
  6. Insulate the attic hatch. An uninsulated hatch is a big hole in your heat shield.

Our blown-in insulation service follows every one of these steps.

blown-in insulation service

Aim Past R40 for Lower Bills and a Warmer Home

R40 insulation runs 6 to 16 inches deep depending on the material. It’s a real improvement over the R-19 in many older Denver homes, but it isn’t the finish line. With our cold winters and hot summer attics, R-49 to R-60 plus full air sealing is the target that actually pays you back.

At Grizzly Insulation Co, we seal the attic first on every job. Our BPI Certified team will measure what you have and show you exactly what you need, and we’re an Xcel Energy rebate partner.

Call (303) 854-6221 to get your attic checked.

Frequently Asked Questions About R40 Insulation

About 11.5 inches of blown cellulose, 11 to 12.5 inches of fiberglass batt, 16 inches of blown fiberglass, or 6 inches of closed-cell spray foam.

Yes, but only slightly. R40 slows heat about 5 percent better than R38.

It’s a practical target when depth is limited. Closed-cell spray foam is often the best way to get there.

That depends on attic size, access, and what’s already up there. Labor and equipment cost about the same either way, so going past R40 to R-49 or R-60 mostly adds material. Federal insulation tax credits and Xcel Energy rebates may help if you qualify.

Not for a new attic. The 2021 IECC level for climate zone 5 is R-60. Existing attics usually don’t have to be upgraded unless you remodel, but check with your local building department.

About RSI 7.0.