Cellulose insulation gives you about R-3.2 to R-3.8 per inch, and most products settle somewhere around R-3.5 to R-3.7. Here’s what surprises people: dense pack and loose fill have almost the same R-value per inch.
So what’s the real difference? Density, settling and airflow. Loose fill goes into open attics at about 1.2 to 1.6 pounds per cubic foot. Dense pack gets stuffed into closed walls and ceilings at 3.5 pounds per cubic foot or more. Packing it that tight stops it from settling and blocks air from moving through it. It doesn’t raise the R-value per inch.
Dense Pack vs Loose Fill Cellulose at a Glance
Factor
Loose fill cellulose
Dense pack cellulose
Where it goes
Open attic floors
Closed walls, sloped ceilings, floors
Installed density
1.2 to 1.6 lb per cubic foot
3.5 lb per cubic foot or more
R-value per inch
R-3.2 to R-3.8
R-3.6 to R-3.8
Settling
15 to 20 percent
Very little when packed right
Air movement
Slows air somewhat
Strongly blocks air
Equipment
Standard blowing machine
High-pressure machine with a small fill tube
R-value is how well insulation slows heat, and higher is better. If you want the basics, read our guide on what R-value means. The U.S. Department of Energy puts cellulose in that same R-3.2 to R-3.8 range on its insulation materials page.
Does Dense Pack Cellulose Have a Higher R-Value per Inch?
This is the biggest myth about cellulose. Cramming it tighter doesn’t keep pushing the R-value per inch up. Building science folks have pointed out that dense pack can even test a hair lower per inch than looser cellulose. Past about 3 pounds per cubic foot, most fiber insulations stop gaining R-value per inch.
Then why bother with dense pack? Because it fixes problems the label doesn’t measure:
It doesn’t settle. Packed tight, the insulation won’t sink and leave an empty gap at the top of the wall.
It blocks air. Dense cellulose resists air flowing through the cavity, and you feel that as comfort even though the label doesn’t show it.
It fills odd spaces. The material packs in around wires, pipes and blocking.
So dense pack wins in walls because of airflow and settling. The R-value per inch has nothing to do with it.
What About Wet-Spray Cellulose?
Wet-spray, sometimes called stabilized cellulose, is a third way to install it. The installer mixes a little water into the fibers and sprays them into open stud walls. The damp fibers stick, and the extra gets scraped off flush with the studs. You have to let it dry completely before the drywall goes up. Its R-value per inch is about the same as the other two methods.
Why Does Loose Fill Cellulose Settle?
Loose fill is blown in light on purpose, so it doesn’t overload the ceiling below. Over the first few months, gravity presses it down. Most loose fill cellulose settles 15 to 20 percent.
That doesn’t ruin anything. It just lowers the depth, and manufacturers plan for it. Every bag lists two depths:
Installed thickness. How deep it goes in on day one.
Settled thickness. How deep it’ll be after settling. The R-value on the bag is based on this one.
A good crew blows to the installed thickness. If they stop at the settled depth on day one, you’ll come up short a few months later.
How Many Inches of Loose Fill Cellulose Do You Need?
As a rough guide, figure about R-3.6 per inch of settled depth. Always double-check the coverage chart on the bag.
Target R-value
Settled depth (about R-3.6 per inch)
Installed depth (allowing for settling)
R-30
8.3 inches
About 10 inches
R-38
10.6 inches
About 12.5 inches
R-40
11.1 inches
About 13 inches
R-49
13.6 inches
About 16 inches
R-60
16.7 inches
About 19.5 inches
Denver is in climate zone 5, and the 2021 International Energy Conservation Code sets attics at R-60 for climate zones 4 through 8. For most Denver attics we recommend R-49 to R-60. Our guides to R40 insulation, R49 insulation and how much insulation is in your attic can help you pick a target.
What R-Value Does Dense Pack Cellulose Give in Walls?
Dense pack fills the whole depth of the cavity, so the total depends on your stud size.
Wall framing
Cavity depth
Dense pack R-value (about)
2×4
3.5 inches
R-13
2×6
5.5 inches
R-20
For walls that are already closed up, the crew drills small holes in the siding or drywall, blows dense pack in through a fill tube, and patches the holes afterward. Our guide to insulating existing interior walls explains how that works.
Does Cellulose Keep Its R-Value in Cold Weather?
Yes, and that matters here in Denver. Tests at Oak Ridge National Laboratory found that some low-density loose fill fiberglass lost R-value in very cold attic conditions, because air could move around inside it. Cellulose is denser and didn’t show the same drop. That makes it a strong pick for cold attics. See our guide to the best attic insulation for cold climates.
How Does Cellulose R-Value Compare to Other Blown Insulation?
Cellulose packs more R-value into each inch than loose fill fiberglass, which runs about R-2.2 to R-2.9 per inch. So cellulose hits the same target with a thinner layer. That comes in handy at the eaves, where the slope of the roof doesn’t leave much room. Compare them in our guides to blown fiberglass insulation and what blow-in insulation is.
What Lowers the Real R-Value of Cellulose?
The number on the bag assumes dry material blown in evenly. In real attics, a few things drag it down:
Moisture. Wet cellulose packs down and loses most of its value.
Low spots. Uneven blowing leaves thin areas that leak heat.
Air leaks. Warm air rising through gaps goes right around the insulation. Seal first. Our guide to air sealing an attic shows how.
Under-blowing. Stopping at the settled depth on day one leaves you short later.
Wind washing. Cold air blowing in at the eaves can stir up loose fill. Baffles stop it.
Cellulose has a few safety points too, like keeping it away from hot light fixtures. Our guide to cellulose insulation dangers goes through each one.
How Do You Check That Cellulose Was Installed to the Right R-Value?
Ask your installer for three things:
The attic card. It lists the product, R-value, installed depth, settled depth and number of bags.
Depth markers. Rulers stapled to the framing let you see the depth at a glance.
The bag count. The coverage chart lists bags per 1,000 square feet for each R-value. Fewer bags than the chart calls for means the job is too thin or too light.
Get the Full R-Value You Pay For, Not Just the Label
Cellulose gives you about R-3.2 to R-3.8 per inch, dense pack or loose fill. Loose fill is the efficient choice for open attics, as long as the crew blows extra depth for settling. Dense pack is the right call for closed walls, because it blocks airflow and stays put.
At Grizzly Insulation Co, we check density, depth and air leaks on every job. Our BPI Certified team will show you exactly what R-value you have and what you need, and we’re an Xcel Energy rebate partner.
Call (303) 854-6221 to book an assessment.
Frequently Asked Questions About Cellulose R-Value per Inch
Yes, as long as the old insulation is dry and clean. The R-values add together. Our guide on whether to remove old insulation first can help you decide.
Cellulose Insulation R-Value per Inch: Dense Pack vs Loose Fill Explained
Cellulose insulation gives you about R-3.2 to R-3.8 per inch, and most products settle somewhere around R-3.5 to R-3.7. Here’s what surprises people: dense pack and loose fill have almost the same R-value per inch.
So what’s the real difference? Density, settling and airflow. Loose fill goes into open attics at about 1.2 to 1.6 pounds per cubic foot. Dense pack gets stuffed into closed walls and ceilings at 3.5 pounds per cubic foot or more. Packing it that tight stops it from settling and blocks air from moving through it. It doesn’t raise the R-value per inch.
Dense Pack vs Loose Fill Cellulose at a Glance
R-value is how well insulation slows heat, and higher is better. If you want the basics, read our guide on what R-value means. The U.S. Department of Energy puts cellulose in that same R-3.2 to R-3.8 range on its insulation materials page.
Does Dense Pack Cellulose Have a Higher R-Value per Inch?
This is the biggest myth about cellulose. Cramming it tighter doesn’t keep pushing the R-value per inch up. Building science folks have pointed out that dense pack can even test a hair lower per inch than looser cellulose. Past about 3 pounds per cubic foot, most fiber insulations stop gaining R-value per inch.
Then why bother with dense pack? Because it fixes problems the label doesn’t measure:
So dense pack wins in walls because of airflow and settling. The R-value per inch has nothing to do with it.
What About Wet-Spray Cellulose?
Wet-spray, sometimes called stabilized cellulose, is a third way to install it. The installer mixes a little water into the fibers and sprays them into open stud walls. The damp fibers stick, and the extra gets scraped off flush with the studs. You have to let it dry completely before the drywall goes up. Its R-value per inch is about the same as the other two methods.
Why Does Loose Fill Cellulose Settle?
Loose fill is blown in light on purpose, so it doesn’t overload the ceiling below. Over the first few months, gravity presses it down. Most loose fill cellulose settles 15 to 20 percent.
That doesn’t ruin anything. It just lowers the depth, and manufacturers plan for it. Every bag lists two depths:
A good crew blows to the installed thickness. If they stop at the settled depth on day one, you’ll come up short a few months later.
How Many Inches of Loose Fill Cellulose Do You Need?
As a rough guide, figure about R-3.6 per inch of settled depth. Always double-check the coverage chart on the bag.
Denver is in climate zone 5, and the 2021 International Energy Conservation Code sets attics at R-60 for climate zones 4 through 8. For most Denver attics we recommend R-49 to R-60. Our guides to R40 insulation, R49 insulation and how much insulation is in your attic can help you pick a target.
What R-Value Does Dense Pack Cellulose Give in Walls?
Dense pack fills the whole depth of the cavity, so the total depends on your stud size.
For walls that are already closed up, the crew drills small holes in the siding or drywall, blows dense pack in through a fill tube, and patches the holes afterward. Our guide to insulating existing interior walls explains how that works.
Does Cellulose Keep Its R-Value in Cold Weather?
Yes, and that matters here in Denver. Tests at Oak Ridge National Laboratory found that some low-density loose fill fiberglass lost R-value in very cold attic conditions, because air could move around inside it. Cellulose is denser and didn’t show the same drop. That makes it a strong pick for cold attics. See our guide to the best attic insulation for cold climates.
How Does Cellulose R-Value Compare to Other Blown Insulation?
Cellulose packs more R-value into each inch than loose fill fiberglass, which runs about R-2.2 to R-2.9 per inch. So cellulose hits the same target with a thinner layer. That comes in handy at the eaves, where the slope of the roof doesn’t leave much room. Compare them in our guides to blown fiberglass insulation and what blow-in insulation is.
What Lowers the Real R-Value of Cellulose?
The number on the bag assumes dry material blown in evenly. In real attics, a few things drag it down:
Cellulose has a few safety points too, like keeping it away from hot light fixtures. Our guide to cellulose insulation dangers goes through each one.
How Do You Check That Cellulose Was Installed to the Right R-Value?
Ask your installer for three things:
We leave an attic card behind on every job our blown-in insulation service does.
Get the Full R-Value You Pay For, Not Just the Label
Cellulose gives you about R-3.2 to R-3.8 per inch, dense pack or loose fill. Loose fill is the efficient choice for open attics, as long as the crew blows extra depth for settling. Dense pack is the right call for closed walls, because it blocks airflow and stays put.
At Grizzly Insulation Co, we check density, depth and air leaks on every job. Our BPI Certified team will show you exactly what R-value you have and what you need, and we’re an Xcel Energy rebate partner.
Call (303) 854-6221 to book an assessment.
Frequently Asked Questions About Cellulose R-Value per Inch
About R-3.2 to R-3.8 per inch. Most people use R-3.5 to R-3.7 for estimates.
Not in any meaningful way per inch. It performs better in walls because it blocks airflow and doesn’t settle.
About 13.5 to 14 inches after settling. Blow about 16 inches on day one to allow for it.
Loose fill settles about 15 to 20 percent. Dense pack that’s packed right settles very little.
Yes, as long as the old insulation is dry and clean. The R-values add together. Our guide on whether to remove old insulation first can help you decide.
Most installers aim for about 3.5 pounds per cubic foot in closed cavities to stop settling.