Skip to main content

Grizzly Insulation Co

All Resources

Which Industrial Insulation Materials Handle High Heat and Process Equipment

Industrial insulation materials ranked by maximum service temperature for high heat process equipment

For hot pipes and process equipment, the main choices are calcium silicate, mineral wool, perlite, flexible aerogel and refractory ceramic fiber. Calcium silicate and mineral wool cover most steam lines and hot tanks, and they’re rated up to about 1,200°F to 1,800°F depending on the type. Ceramic fiber goes up to about 3,000°F, so it’s used in furnaces and kilns. Foam insulation like polyiso and elastomeric is for cold or warm lines, not hot ones.

Pick the wrong one, and it can melt, soak up water or leave a pipe hot enough to burn someone. Our Grizzly Insulation Co crews work with commercial and industrial owners around Denver, so here’s what each material can handle.

Industrial insulation materials ranked by maximum service temperature for high heat process equipment

What Temperature Can Each Industrial Insulation Material Handle?

The National Insulation Association’s Mechanical Insulation Design Guide lists the temperature range for each material, based on ASTM standards:

MaterialApprox. service temperature
Calcium silicate80°F to 1,700°F
Mineral wool block and boardUp to 1,800°F
Fiberglass pipe and boardUp to about 850°F to 1,000°F
Perlite80°F to 1,200°F
Flexible aerogel-321°F to 1,200°F
Cellular glass-450°F to 800°F
Refractory ceramic fiberUp to about 3,000°F
PolyisoUp to about 300°F
Elastomeric foamUp to about 220°F to 350°F

The limits change by type and brand, so check the data sheet for the product you buy. Also, a high temperature rating doesn’t mean a high R-value. Some heat-proof materials still need a thick layer to cut heat loss. Our page on what R-value means explains the difference.

Which Insulation Is Best for High-Temperature Steam Lines?

Calcium silicate or mineral wool. Calcium silicate is hard and strong, so it holds up where people step on it or where pipe hangers press on it. Mineral wool is lighter and easier to cut, and it takes high heat well. Neither one burns.

Fiberglass pipe insulation is fine on lines that run cooler. Our page on whether fiberglass insulation is flammable explains its limits.

When Should You Use Aerogel or Perlite?

Use aerogel when there’s no room. A thin aerogel blanket insulates about as well as a much thicker layer of other materials, which helps on crowded pipe racks. It costs more per square foot.

Use perlite on hot pipes and tanks where rust under the insulation is a worry. Many perlite products are made to resist water. Our page on the highest R-value insulation explains why thin, high-performance materials cost more.

Which Materials Handle Extreme Heat Like Furnaces and Kilns?

Ceramic fiber and microporous insulation. Ceramic fiber is rated up to about 3,000°F and lines furnaces, kilns and heat-treating ovens. Microporous panels go above 1,800°F in a thin layer. Only trained crews with the right gear should install these.

Ceramic fiber dust bothers skin and lungs, so cutting it or tearing it out needs respirators and a careful cleanup. Gaps in an old furnace lining also burn a lot of extra fuel. Our page on energy efficient insulation explains how to rank fixes by savings.

energy efficient insulation

Can Foam Insulation Be Used on Process Equipment?

Only on cold or warm lines. Polyiso and elastomeric foam work well on chilled water, refrigeration and cooler process lines, where the main job is stopping sweat. Cellular glass works on both very cold lines and fairly hot ones.

We sometimes hear that any foam will do on a hot pipe. It won’t. Polyiso tops out around 300°F, and elastomeric is lower. On a 400°F steam line, they’d fall apart. When we size up a plant, we check each line’s temperature first and only then pick a material. Our commercial insulation team does that review. For foam basics, see what closed cell spray foam is.

What Else Matters Besides Temperature Rating?

Water, the outer jacket and how often someone needs to get at the part. Pipe insulation outdoors or in wet areas needs a sealed metal or PVC jacket. Valves and flanges that get worked on often should get removable blankets instead of fixed insulation. Our page on whether insulation dries out explains why wet insulation stops working.

Old pipe insulation can contain asbestos, so test before you remove anything. Our insulation removal crews can tell you when a test is needed.

What Is Corrosion Under Insulation?

It’s rust that forms on a pipe or tank under wet insulation. Water gets in through a torn jacket or an open seam, soaks the insulation and sits on the steel where nobody can see it. Lines that run between about 25°F and 350°F, or that turn on and off a lot, are most at risk.

The fix is keeping water out. That means sealed jackets, materials that resist water, and checking seams and pipe supports on a schedule. Our page on wet crawl space insulation shows how water ruins insulation in houses too.

wet crawl space insulation

Which Industrial Insulation Materials Make Sense in Denver?

Plants here deal with cold winters, dry air and outdoor pipes that get snow and freeze-thaw. Mineral wool or calcium silicate with a good jacket handles most hot lines in Denver. Cellular glass or elastomeric works for chilled lines. Breweries, food plants and hospitals around Denver often use several materials on one site. For cold-weather basics, see whether insulation keeps cold in.

Match Industrial Insulation Materials to the Heat They Have to Handle

Start with the temperature. Use calcium silicate or mineral wool on hot lines, ceramic fiber in furnaces, and foam only where things run cold or warm. Add a good jacket, and the insulation will last for years.

Need help with insulation at a Denver plant or facility? Grizzly Insulation Co can help you sort it out. We’re BPI Certified and an Xcel Energy rebate partner.

Frequently Asked Questions About Industrial Insulation Materials

Calcium silicate and mineral wool are the most common. Ceramic fiber is used for the hottest jobs.

Refractory ceramic fiber, rated up to about 3,000°F.

Only up to about 300°F. It’s better for cold or warm lines.

Where space is tight, yes. It insulates well in a thin layer.

Outdoors and in wet areas, yes. The jacket keeps water out of the insulation.